Chapter 5 XLT
®
Pro Options
GRAPH ACCUMULATE
ON
OFF
TO CHANGE PRESS
ENTER
(Display section)
24. Accumulate
ON combines SignaGraph™ information over
multiple loop passes, OFF shows SignaGraph™
information only from the last sweep of the loop.
Accumulate allows the SignaGraph™ to continually
collect information. This collecting of information
continues from one sweep of the loop to the next.
Eventually, if only ACCUMULATE is selected,
the SignaGraph™ will completely fill, requiring
that the TRIGGER by squeezing and releasing to
clear it so that further information may be viewed.
FADE is suggested to be used in combination with
ACCUMULATE so that non-current information
gradually disappears and excessive TRIGGERing is
not required. FADE will gradually reset or clear the
SignaGraph™ to eliminate old information.
Tips - ON is suggested,
since it takes several
sweeps of information to
recognize trends.
GRAPH AVERAGING
ON
OFF
TO CHANGE PRESS
ENTER
25. Average
Emphasizes the most common or predominate
SignaGraph™ indications.
AVERAGE does not necessarily allow showing of
all the available information on the SignaGraph™.
It averages the information received, and shows this
average on the SignaGraph™. When used in combi-
nation with ACCUMULATE it has more informa-
tion to average, which results in more accurate
indications of trends. FADE is suggested to clear
the display of old information, rather than excessive
TRIGGERing.
Tips - Most beneficial
when used in combination
with ACCUMULATE.
AVERAGE ON is sug-
gested as it reduces
indications uncharacteris-
tic of a particular target,
which may occur due to
loop angle or target
positioning in the ground.
(Display section)
If ACCUMULATE is OFF, and AVERAGE
is OFF, then SINGLE SWEEP is active.
SINGLE SWEEP displays SignaGraph™
information received during the current sweep
of the loop, no more and no less. The next
sweep of the loop will clear all information
from the SignaGraph™ and list the informa-
tion received only within that sweep. Fade is
not needed in the SINGLE SWEEP mode as
each pass of the loop will clear the display
and provide current information automati-
cally. Several SignaGraph™ indication
samples occur during each sweep of the loop.
It is therefore normal to see one or more
SignaGraph™ bars, even in the SINGLE
SWEEP mode.