Rx Gain - (Pre-Amp) Adjusts receive signal amplication. Affects sensitivity, depth,
and interference from external noise.
Tx Boost - Boosts transmit signal for use in low mineral ground.
CAUTION - prolonged use will increase battery drain.
Discrimination - Adjusts level of sensitivity to targets. Affects depth.
All Metal - Adjust detection signal in All Metal circuit. Effects depth and width of
target response.
Sensitivity
Tips ...
LIVE CONTROLS - SENSITIVITY
Sensitivity
Sensitivty Zoomed
Probe -
Percentage indicator of signal capacity-
to-noise ratio, and a Best Gain calculation
for MAX performance.
a. Signal % = return from ground.
b. Noise % = external electrical and
ground noise.
c. Best Gain = RX Gain reasonable level
(considering all other current settings).
With the loop on the ground, note “Best
Gain”. Adjust RX Gain to match.
The “preset” factory program settings are always marked with a checkmark or
the value is underlined. When changing Sensitivity on RX Gain, re-
ground balance is recommended - see Ground Balance/Tracking page 9.